product
Rebundancy - A4000
A4000
Inputs
There are four inputs on the rear of the instrument - two signal and two DC control. The inputs are a primary source (A) and a secondary source (B). These sources are switched, dependant on the control input, one for the primary (A) and the other for the secondary (B).
The control lines are 0 ~ 5v DC active high (+5v DC).
Output
There is one single signal output on the rear panel. This is the output from either signal input, dependant on the control input
Typical uses
The Quartzlock A4000 is installed in many remote, unmanned telecommunications base stations to ensure continuous time and frequency standards are available for mission critical applications.
Applications
Interface
Inputs
a) Signal A & B 1 - 100 MHz sine wave, 10 dBm nom into 50W nom.
b) Control A & B 0 - 5v Control Line Active High
Outputs
a) Signal A or B dependant on control A & B
Product Options
This product can have the following options applied to change its specification
Option N - No Options Available